Washer-disinfector HYG 5 The complete solution with service/warranty package, hygiene package and washer-disinfector
Array
(
    [0] => Array
        (
            [id] => 72
            [date_time] => 2020-02-14 13:42:49
            [titel_en] => Brochure HYG 5
            [titel_de] => Broschüre HYG 5
            [status] => 1
            [kategorie] => 24
            [datei] => /uploads/produkte/dokumente/200214_hyg5_broschur2_v1-0_SCREEN.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => 
            [beschreibung_en] => 
            [typ] => 2
            [produkte] => 
        )

    [1] => Array
        (
            [id] => 6
            [date_time] => 2018-09-19 09:54:48
            [titel_en] => EC-Material safety data sheet Oxides Thermo Tabs
            [titel_de] => EG-Sicherheitsdatenblatt Oxides Thermo Tabs
            [status] => 1
            [kategorie] => 10
            [datei] => /uploads/produkte/dokumente/SDB_ICMedical_Thermo_Tabs_DE_2018.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Das Sicherheitsdatenblatt der Oxides Thermo Tabs benötigen Sie für Ihre Unterlagen, bitte bewahren Sie diese sorgfältig auf.
            [beschreibung_en] => You need the material safety data sheet of the Oxides Thermo Tabs for your documents, please keep them carefully.
            [typ] => 3
            [produkte] => 
        )

    [2] => Array
        (
            [id] => 7
            [date_time] => 2018-09-19 09:56:03
            [titel_en] => EC-Material Safety Data Sheet Service Tabs
            [titel_de] => EG-Sicherheitsdatenblatt Service Tabs
            [status] => 1
            [kategorie] => 10
            [datei] => /uploads/produkte/dokumente/SDB_Service_Tabs_V2.0.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Das Sicherheitsdatenblatt der Service Tabs benötigen Sie für Ihre Unterlagen, bitte bewahren Sie diese sorgfältig auf.
            [beschreibung_en] => You need the material safety data sheet of the service tabs for your documents, please keep them carefully.
            [typ] => 3
            [produkte] => 
        )

    [3] => Array
        (
            [id] => 8
            [date_time] => 2018-10-10 11:39:21
            [titel_en] => EC-Material safety data sheet Medical white oil
            [titel_de] => EG-Sicherheitsdatenblatt Medizinisches Weißöl
            [status] => 1
            [kategorie] => 10
            [datei] => /uploads/produkte/dokumente/SDB_IC_Medizinisches_Wei____l_V1.0.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Das Sicherheitsdatenblatt Ihres Medizinisches Weißöles benötigen Sie für Ihre Unterlagen, bitte bewahren Sie diese sorgfältig auf.
            [beschreibung_en] => You need the safety material data sheet of the medical white oil for your documents, please keep them carefully.
            [typ] => 3
            [produkte] => 
        )

    [4] => Array
        (
            [id] => 70
            [date_time] => 2020-02-03 10:16:20
            [titel_en] => Installation requirements washer-desinfector HYG 5
            [titel_de] => Installationsvoraussetzungen Thermodesinfektor HYG 5
            [status] => 1
            [kategorie] => 0
            [datei] => /uploads/produkte/dokumente/Kundendokument_Installation_HYG_5_V1.2.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Bitte prüfen Sie die Installationsvoraussetzungen für Ihren Thermodesinfektor HYG 5 sorgfältig und senden Sie dieses Dokument samt Bestellung unterschrieben an IC Medical zurück.
            [beschreibung_en] => Please check the installation requirements for your washer-disinfector HYG 5 carefully and return this document to IC Medical with your signed order.
            [typ] => 4
            [produkte] => 
        )

    [5] => Array
        (
            [id] => 71
            [date_time] => 2020-02-06 10:31:56
            [titel_en] => IC Medical Productportfolio
            [titel_de] => IC Medical Produktportfolio
            [status] => 1
            [kategorie] => 0
            [datei] => /uploads/produkte/dokumente/200225_ic_dinlang_8seiter_produktportfolio_v1-2_SCREEN.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => 
            [beschreibung_en] => 
            [typ] => 2
            [produkte] => 
        )

)
Our Washer-disinfector HYG 5 is only available in direct sales

✓ 1-program technology
✓ Preparation on two levels
✓ Made by us in Baden-Württemberg
✓ Device warranty up to 5 years
✓ Nationwide own service technicians 

Detailed product information

Features

Service, warranty and hygiene package

IC Medical has developed a comprehensive warranty and service package for the HYG 5. Within this framework we will repair or replace parts if there are any faults in material or workmanship. IC Medical Service will carry out this work without charging for material or labour costs.

In detail this means:

 

The device guarantee: For the good feeling of safety

3-5 years without cycle limitation, calculated from date of installation qualification.

Only possible in connection with service package.

 

The IC Medical original parts warranty: High-quality and precisely matched

2 years without cycle limitation, calculated from the date of installation by IC Medical Service

 

The longLife guarantee: against rusting through

10 years without cycle limitation, calculated from date of installation qualification

 

The IC Medical hygiene package

Validation, all you want: As a certified validation company, we can also take over this part and carry it out with our expertise.

Dr. med. dent. Wever about our washer-disinfectors

"The device is simply effective, inexpensive and also convinces with its low water consumption."

Innovative for more safety

For our HYG 5 we have developed an innovative pump technology and a new water supply system. Both ensure the cleaning and disinfection of the outer surfaces of your instruments. And it ensures the disinfection of all interiors of the hollow instruments used.

Comfortable loading

With its new interior concept, the HYG 5 as an under-table or built-in unit offers you extremely comfortable loading. The upper basket can be pulled out 100 percent and carries up to 6 kg of medical instruments. The HYG 5 can process a total of three autoclave loads per cycle. This favours the entire workflow and reduces costs.

Short program time for more efficiency

Our HYG 5 washer-disinfector prepares even demanding batches reliably, quickly and safely; even complex hollow bodies. The design is stable and powerful. Two processing levels enable greater flexibility and smooth operation even with high or changing instrument requirements. Even with high or changing instrument requirements, the HYG 5 delivers full power with the shortest processing time.

Dr. med. Strasser about our Oxides ThermoTabs

"The ThermoTab cleaning chemistry is particularly simple, like at home in a dishwasher."

Process chemicals - simple, perfectly dosed, space-saving to store

Our new water supply system guarantees the cleaning and disinfection of the outer surface as well as the secure disinfection of all interiors of hollow instruments. A special innovation is our own pump circuit with our Pulso system for the injection bar. This system with an adapted medical silicone tube ensures gentle preparation, cleaning and disinfection of hollow instruments.

For use in dental officies, the washer-disinfector HD 450 Injection PRO offers the possibility of reprocessing up to eight handpieces and contra-angle handpieces.

A wide range of accessories provides the scope for further flexible use. With the Flexio adapter for tartar tips, for example, up to six tartar or ultrasonic tips can be prepared per batch.

For use in the medical officies of dermatologists, ENT doctors, urologists or surgeons, it allows the reprocessing of up to eighteen hollow body instruments such as Luer suction cups.

IC HotDrying process

With our IC HotDrying process, the HYG 5 achieves optimum drying results. After opening, you hold stain-free instruments in your hands as you need them.

Batch release directly on the display for more convenience

Visual inspection is mandatory. With the HYG 5 we make batch release even easier for you: You can then release it directly on the device display. Our software transfers the release to the batch report at the same time.

Interfaces for legally compliant documentation

Safe instrument preparation includes legally compliant process documentation with all prescribed parameters. The HYG 5 offers you interfaces for easy reading and archiving of data via network connection or USB stick. For this purpose we provide our documentation software IC Printer. In addition, the documentation can be integrated into your existing practice software via other interfaces (Segosoft, DOGma (DIOS)).

Dr. med. vet. Stumpf about our washer-disinfectors

"With the washer-disinfector, we meet the legal requirements and increase occupational safety."

IC ion exchange cartridge for valid water quality

Fully demineralized water ensures the maximum service life of your equipment and instruments. For complete desalination we offer the IC ion exchange cartridge.

The IC Touch Control Display of the HYG 5 shows you immediately when the performance of your VE cartridge is exhausted. Alternatively, your batch report can provide information on this.

Installation requirements

All you need to operate the HYG 5 washer-disinfector is the following:

  • Power supply 220...240 V; 50/60 Hz; 16A
  • Cold water connection 3/4 inch
  • Waste water connection DN19
  • Deionised water

Specifications

 HYG 5
Type name HYG 5
Articel number 120 005
Unit dimensions (HxWxD)
incl. base
82 x 48,5 x 55 cm
10,5 x 48,5 x 55 cm
Unit dimensions table-top (HxWxD) 71 x 48,5 x 55 cm
Throat (T) 33 cm

Washing chamber (HxWxD) 

H = maximum loading height

D = maximum loading depth

32 x 41,5 x 45 cm
Weight (empty) 30,4 kg
Soil pollution ca. 1200 N/m²
Volume of the washing chamber 101 liter
Electrical connection 220...240 V, 50/60 Hz, 16 A
Max. sound power (cleaning) 58 dBA
Waste heat 0,55 kW/h (2,7 MJ/h)
Ambient temperature 15 - 35°C
Relative humidity 30 - 60%
Max. installation altitude 2000 m
Installation category 2
Air pressure 75 kPa - 106 kPa
Cold water / demineralized water connection 3/4"
Waste water connection DN19
Quality of the water

at least drinking water quality according to the Drinking Water Ordinance (DrinkW2001) or compliance with local regulations

Minimum water inlet pressure 50 kPa (0,5 bar)
Maximum water inlet pressure 1000 kPa (10 bar)
Max. waste water temperature 93°C
Waste water quantity per hour ca. 20 l (at smaller intervals)
Drain pump capacity max. 20 l/min (Volume in waste water hose)
Length of inlet and outlet hoses Inlet hoses 1,50 m / Demineralised water/reverse osmosis inlet 1.50 m / Outlet hoses 2,30 m
Length of the mains cable 2 m
Internal memory up to 3000 Zyklen
Interfaces USB, network (RJ45)
Degree of pollution Category 2
Protection class (to IEC 60529) IP20
CE label 0297
Standard conformity DIN EN ISO 15883-1/2, EN 61010-2-040
Array
(
    [0] => Array
        (
            [id] => 72
            [date_time] => 2020-02-14 13:42:49
            [titel_en] => Brochure HYG 5
            [titel_de] => Broschüre HYG 5
            [status] => 1
            [kategorie] => 24
            [datei] => /uploads/produkte/dokumente/200214_hyg5_broschur2_v1-0_SCREEN.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => 
            [beschreibung_en] => 
            [typ] => 2
            [produkte] => 
        )

    [1] => Array
        (
            [id] => 6
            [date_time] => 2018-09-19 09:54:48
            [titel_en] => EC-Material safety data sheet Oxides Thermo Tabs
            [titel_de] => EG-Sicherheitsdatenblatt Oxides Thermo Tabs
            [status] => 1
            [kategorie] => 10
            [datei] => /uploads/produkte/dokumente/SDB_ICMedical_Thermo_Tabs_DE_2018.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Das Sicherheitsdatenblatt der Oxides Thermo Tabs benötigen Sie für Ihre Unterlagen, bitte bewahren Sie diese sorgfältig auf.
            [beschreibung_en] => You need the material safety data sheet of the Oxides Thermo Tabs for your documents, please keep them carefully.
            [typ] => 3
            [produkte] => 
        )

    [2] => Array
        (
            [id] => 7
            [date_time] => 2018-09-19 09:56:03
            [titel_en] => EC-Material Safety Data Sheet Service Tabs
            [titel_de] => EG-Sicherheitsdatenblatt Service Tabs
            [status] => 1
            [kategorie] => 10
            [datei] => /uploads/produkte/dokumente/SDB_Service_Tabs_V2.0.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Das Sicherheitsdatenblatt der Service Tabs benötigen Sie für Ihre Unterlagen, bitte bewahren Sie diese sorgfältig auf.
            [beschreibung_en] => You need the material safety data sheet of the service tabs for your documents, please keep them carefully.
            [typ] => 3
            [produkte] => 
        )

    [3] => Array
        (
            [id] => 8
            [date_time] => 2018-10-10 11:39:21
            [titel_en] => EC-Material safety data sheet Medical white oil
            [titel_de] => EG-Sicherheitsdatenblatt Medizinisches Weißöl
            [status] => 1
            [kategorie] => 10
            [datei] => /uploads/produkte/dokumente/SDB_IC_Medizinisches_Wei____l_V1.0.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Das Sicherheitsdatenblatt Ihres Medizinisches Weißöles benötigen Sie für Ihre Unterlagen, bitte bewahren Sie diese sorgfältig auf.
            [beschreibung_en] => You need the safety material data sheet of the medical white oil for your documents, please keep them carefully.
            [typ] => 3
            [produkte] => 
        )

    [4] => Array
        (
            [id] => 70
            [date_time] => 2020-02-03 10:16:20
            [titel_en] => Installation requirements washer-desinfector HYG 5
            [titel_de] => Installationsvoraussetzungen Thermodesinfektor HYG 5
            [status] => 1
            [kategorie] => 0
            [datei] => /uploads/produkte/dokumente/Kundendokument_Installation_HYG_5_V1.2.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => Bitte prüfen Sie die Installationsvoraussetzungen für Ihren Thermodesinfektor HYG 5 sorgfältig und senden Sie dieses Dokument samt Bestellung unterschrieben an IC Medical zurück.
            [beschreibung_en] => Please check the installation requirements for your washer-disinfector HYG 5 carefully and return this document to IC Medical with your signed order.
            [typ] => 4
            [produkte] => 
        )

    [5] => Array
        (
            [id] => 71
            [date_time] => 2020-02-06 10:31:56
            [titel_en] => IC Medical Productportfolio
            [titel_de] => IC Medical Produktportfolio
            [status] => 1
            [kategorie] => 0
            [datei] => /uploads/produkte/dokumente/200225_ic_dinlang_8seiter_produktportfolio_v1-2_SCREEN.pdf
            [sprache] => ["de","en"]
            [beschreibung_de] => 
            [beschreibung_en] => 
            [typ] => 2
            [produkte] => 
        )

)

Brochures

  •  Brochure HYG 5 ([pdf], 5,48 MB)
  •  IC Medical Productportfolio ([pdf], 977,32 KB)

Safety data sheets

  •  EC-Material safety data sheet Oxides Thermo Tabs ([pdf], 457,79 KB)
    You need the material safety data sheet of the Oxides Thermo Tabs for your documents, please keep them carefully.
  •  EC-Material Safety Data Sheet Service Tabs ([pdf], 357,62 KB)
    You need the material safety data sheet of the service tabs for your documents, please keep them carefully.
  •  EC-Material safety data sheet Medical white oil ([pdf], 326,11 KB)
    You need the safety material data sheet of the medical white oil for your documents, please keep them carefully.

Installation and instructions

  •  Installation requirements washer-desinfector HYG 5 ([pdf], 553,29 KB)
    Please check the installation requirements for your washer-disinfector HYG 5 carefully and return this document to IC Medical with your signed order.

Product advice / Price inquiry

How can we help you?

My contact details

Upcoming events

Logo
October 16 till 17th 2020
FACHDENTAL exhibition Southwest / id information days dental Stuttgart
Logo
October 29st till 31rd 2020
54nd advanced training event for ear, nose and throat physicians
Logo
March 9th till 13th 2021
39th International Dental Show - IDS

Trade show and event overview